Save 5€ now!Subscribe to our newsletter!
Spring offers: The bargains are blooming!

  Camping Specialist Since 1958
  Free shipping from 50 €
Service
EN | DE
Language:
Deutsch
English
Nederlands
Österreich
Français
Italiano
Español
Shipping Country:
Austria
Belgium
Bulgaria
Czech Republic
Croatia
Denmark
Estonia
Finland
France
Germany
Greece
Hungary
Ireland
Italy
Lithuania
Latvia
Liechtenstein
Luxembourg
Malta
Netherlands
Norway
Poland
Portugal
Romania
Slovakia
Slovenia
Spain
Sweden
Switzerland
Tents Tents
All products in "Tents"
Outdoor & Leisure Outdoor & Leisure
All products in "Outdoor & Leisure"
Furniture Furniture
All products in "Furniture"
Household Household
All products in "Household"
Water & Sanitation Water & Sanitation
All products in "Water & Sanitation"
Electronics Electronics
All products in "Electronics"
Caravanning Caravanning
All products in "Caravanning"
Heating & Cooling Heating & Cooling
All products in "Heating & Cooling"
Clothing Clothing
All products in "Clothing"
Trending Topics Trending Topics
All products in "Trending Topics"
New New
All products in "New"
Sale Sale
All products in "Sale"
Store Store
Change store
Address

To the store page
Language & Country
Language
Shipping country

Victron Energy Cyrix-ct intelligent battery coupler 12 / 24 V 120 A

(0)  
59,99
Prices incl. statutory VAT, free shipping
Item number: 162609
 
Availability: Available in 3-5 working days
 Added

Product details

12/24 V automatic detection of the voltage range No voltage loss
The starter battery gets priority Parallel connection for emergency (Start Assist)

Product description

The Cyrix Battery Coupler is a high performance microprocessor controlled relay that automatically connects batteries in parallel when one of them reaches a predetermined voltage level (indicating that the battery is being charged) and, disconnects the batteries again when the voltage drops below the float voltage level (indicating that one or both batteries are being discharged). Cyrix battery couplers are excellent for replacing isolation diodes. Their main feature is that there is virtually no voltage loss, so there is no need to increase the output voltage of the alternators or battery chargers.

12/24 V automatic voltage range detection
The Cyrix-ct 12/24 automatically detects the system voltage.

No voltage loss

Cyrix battery couplers are excellent for replacing isolation diodes. Their main feature is that there is practically no voltage loss, so there is no need to increase the output voltage of the alternators or battery chargers.

The starter battery gets priority

In a typical setup, the alternator is connected directly to the starter battery. The auxiliary battery and possibly a bow thruster and other batteries are each connected to the starter battery through Cyrix battery couplers. When a Cyrix detects that the starter battery has reached terminal voltage, it closes to allow parallel charging of the other batteries.

Voltage detection in both directions and power supply from both batteries

The Cyrix measures the voltage of both connected batteries. It therefore also turns on when, for example, the additional battery is being charged by a battery charger.
The Cyrix-ct 12/24 has a dual power supply. Therefore, it will close even if the voltage at one of the batteries is too low to operate the Cyrix.
To avoid unintended operation during installation or if one of the batteries has been disconnected, the Cyrix-ct 12/24 will not close if the voltage at either battery terminal is below 2 V (12 V battery) or 4 V
(24 V battery in place).

Parallel connection for emergency (Start Assist)

The Cyrix can also be switched on by a push button (Cyrix stays on for 30 seconds) or by a switch to connect the batteries in parallel by hand.
This is especially useful in an emergency when the starter battery is discharged or damaged.

Technical data
  • LED status indicator: No
  • Continuous current: 120 A
  • Rated starting current (5 seconds): 180 A
  • Connect voltage: From 13 V to 13.8 V and 26 to 27.6 V with intelligent trend detection
  • Disconnect voltage: From 11 V to 12.8 V and 22 to 25.7 V with intelligent trend detection
  • Current consumption when open: < 4 mA
  • Current consumption when closed: 12 V : 220 mA 24 V : 120 mA
  • Start Assist: Yes (Cyrix stays on for 30 seconds)
  • Protection class: IP54

Features

Type battery Accessories
Colour black
Weight 110 g
Input voltage From 13 V to 13.8 V and 26 to 27.6 V
Charging current 120 A
Operating voltage 12/ 24 V
Design Standard
Dimensions (LxWxH) 80 x 46 x 46 mm

Similar items

More from this brand

Your session will run in
10 : 00
Min. Sec.